Speaker
Linh Do
(INST Hanoi (VINATOM))
Description
The thickness of the $^{11}$B target was determined by using $^{11}$B(p,p$_{0})$ elastic reaction. The proton beams were accelerated up to the energy range from 1.1 - 1.9 MeV by the Pelletron 5SDH-2 accelerator at Hanoi University of Science. The measured $^{11}$B target thickness is 65.45 ± 3.78 $\mu g/cm^2$, lower than the value of 74 $\mu g/cm^2$ from the target supplier. This result demonstrates the capability of this method in the target thickness determination.
Keywords: thickness, boron target, proton – nucleus elastic scattering, Pelletron.
Presentation type | Oral presentation |
---|
Primary author
Linh Do
(INST Hanoi (VINATOM))
Co-authors
Dr
Xuan-Chung Le
(Institute for Nuclear Science and Technology (VINATOM))
Dr
Marco La Cognata
(Istituto Nazionale di Fisica Nucleare, Laboratori Nazionali del Sud)
Mr
The-Anh Tran
(Hanoi University of Science, Vietnam National University)
Mr
Tuan-Anh Nguyen
(Hanoi Irradiation Center, VINATOM)
Ms
Thi-Hoa Bui
(Hanoi University of Science, Vietnam National University)
Prof.
Duc-Khue Pham
(Institute for Nuclear Science and Technology, VINATOM)
Dr
Michele Sferrazza
(Université Libre de Bruxelles, Bruxelles)
Dr
The-Nghia Nguyen
(Hanoi University of Science, Vietnam National University)
Dr
G.G. Rapisarda
(University of Catania)
Dr
Dinh-Trong Tran
(Institute of Physics, Vietnam Academy of Science and Technology)